Issue

  • Notification email

Problem Summary: Cluster - SwitchAttachedMixedDomain_Alert
Detailed Problem Description: Alert ID: SwitchAttachedMixedDomain_Alert
           Resource: storage_switch-mixed-domain_cluster-sw-a
           Severity: Major
 Indication Time: Wed Jul 22 04:52:24 2026
           Suppress: false
        Acknowledge: false
     Probable Cause: Switch "cluster-sw-a" is cabled to nodes and shelves
                     "cluster-01, cluster-02, cluster-03, cluster-04, 
                     cluster-05, cluster-06, cluster-07, cluster-08, 
                     1.3, 1.2, 1.1, and 1.0" from multiple storage domains.
    Possible Effect: This configuration is not supported.
 Corrective Actions: Each switch must be cabled to node and shelf ports
                     from the same storage domain.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.