SingleSwitchToShelf_Alert and MccIp_PortOfflineAlert after ONTAP upgrade
Applies to
- AFF A90
- ONTAP upgrade from 9.16.1P11 to 9.18.1P5
- Metrocluster configuration MCC-IP
Issue
- After ONTAP upgrade, Cluster 01 of Metrocluster configuration reports SingleSwitchToShelf_Alert and MccIp_PortOfflineAlert. Example:
[?] Tue Jul 21 11:39:52 +0200 [Cluster01-01: nchmd: hm.alert.raised:alert]: Alert Id = SingleSwitchToShelf_Alert , Alerting Resource = Cluster01-01 raised by monitor node-connect
[?] Tue Jul 21 11:42:23 +0200 [Cluster01-01: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process nchm: SingleSwitchToShelf_Alert[Cluster01-01].[?] Tue Jul 21 13:12:52 +0200 [Cluster01-01: nchmd: hm.alert.cleared:notice]: Alert Id = MccIp_PortOfflineAlert , Alerting Resource = Cluster01-01_e3b_e3b-20 cleared by monitor node-connect
[?] Tue Jul 21 14:12:52 +0200 [Cluster01-01: nchmd: hm.alert.raised:alert]: Alert Id = MccIp_PortOfflineAlert , Alerting Resource = Cluster01-01_e3b_e3b-20 raised by monitor node-connect
- One of the switch's management IP addresses is unreachable and also leading to intermittent SwitchInfoUpdateFailure_Alert and SwitchUnreachable_Alert.