Issue
- After adding the new shelf to the system, there is a single path to the disk shelf alert.
Node-02
node-connect SinglePathToDiskShelf_Alert 4168583XXXX905936 SAS-connect
Major Cable_tamper
Controller Node-02 has only a single-path configuration to disk shelf 2.10.
This might occur when the controller does not have dual-path configuration to stack 2, a SAS HBA port on the controller connected to the disk shelf is disabled, or shelf-to-shelf cabling is incorrect.
- Also, we observed that the system is in a mixed path.
NetApp Release 9.13.1P6: Tue Dec 5 11:06:25 EST 2023
System ID: 0538168XXX (Node-01); partner ID: 0538168XXX (Node-02)
System Serial Number: 652040000XXX (Node-01)
System Rev: B1
System Storage Configuration: Mixed-Path HA
NetApp Release 9.13.1P6: Tue Dec 5 11:06:25 EST 2023
System ID: 0538168XXX (Node-02); partner ID: 0538168XXX (Node-01)
System Serial Number: 652040000XXX (Node-02)
System Rev: B1
System Storage Configuration: Mixed-Path HA