Shelf fault error with IOM not installed
Applies to
- FAS2650
 - ONTAP 9
 
Issue
- Storage fault and EMS reports IOM not installed
 STORAGE-FAULTlog section in autosupport reports below
Enclosure Status: critical
Channel: 0b
Shelf: 2
Shelf Type: DS224-12
Vendor Unique Element 83-IOM12: (SAS)
Element Status         Status Bytes  Status Descriptions
  1: NOT INSTALLED     05,00,00,00   
  2 [IOM12 B]    : NONCRITICAL       03,0C,00,A0   BACKPLANE VPD FAULT, MASTER, RESERVED, RESERVED
EMS-LOG-FILE.GZlog section in autosupport reports below
[NodeName: dsa_worker0: ses.status.electronicsWarn:error]: DS224-12 (S/N SHFHU2036000023) shelf 2 on channel 0b environmental monitoring warning for SES electronics 1: not installed.  This module is on the rear of the shelf at the top left.
HA Group Notification (SHELF_FAULT) ERROR
- Issue persists on replacing the affected IOM, parter IOM, shelf chassis
 