Shelf Module appearing as NOT INSTALLED

Views:
300
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:
4/29/2025, 2:09:38 AM

Applies to

  • ONTAP 9
  • DS224C Disk Shelf
  • IOM12

Issue

  • System is in mixed-path
  • The IOM is not correctly installed or is faulty
  • ::> node run -node * storage show fault -v
     
    [truncated]
    Enclosure Electronics:
    Element Status                      Status Bytes  Status Descriptions
      1 [IOM12 A]    : OK                01,00,01,00   REPORT
      2 NOT INSTALLED                    05,00,00,00  

    In sysconfig no firmware is listed for the shelf module

    ::> node run -node * sysconfig -a
    		Shelf 0: DS212-12  Firmware rev. IOM12E A: 0201  IOM12E B: 0201
    		Shelf 1: DS212-12  Firmware rev. IOM12 A: 0250  IOM12 B: 0250
    		Shelf 2: DS212-12  Firmware rev. IOM12 A: 0250   B: ----
    
  • No link LEDs on for the SAS cables connecting to the IOM from controller or other shelve

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.