Shelf ID Delta error reported
Applies to
- ONTAP 9
- FAS/AFF Systems
Issue
- The following shelf fault errors are seen in the event logs:
[Node-01: dsa_worker2: ses.status.ModuleError:alert]: DS212-12 (S/N SHJSG123456789) shelf 0 on channel 0b SAS expander error for SAS shelf electronics 1: critical status; Shelf ID changed. This module is on the rear of the shelf at the top left, on shelf module A.
[Node-01: dsa_worker2: ses.shelf.changedId:error]: Disk shelf module 2 on disk shelf 0b.0 indicates that the disk shelf ID has been changed since the disk shelf module was powered on. This module is on the rear of the shelf at the top right, on shelf module B.
[Node-01: statd: monitor.shelf.fault:alert]: Critical fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.
[Node-01: statd: callhome.shlf.fault:error]: Call home for SHELF_FAULT
- As per the autosupport logs, the shelf ID is set correctly:
::> system node run -node <node> -command sysconfig -a
Shelf 0: DS212-12 Firmware rev. IOM12E A: 0250 IOM12E B: 0250
Shelf 1: DS460-12 Firmware rev. IOM12B A: 0141 IOM12B B: 0141
- The shelf ID delta error is seen on both modules of the shelf:
::> system node run -node <node> storage show fault
Enclosure Status: non-critical
Channel: 0a
Shelf: 0
Shelf Type: DS212-12
Product Serial Number: SHJSG123456789
Module Type: IOM12E
Vendor Unique Element 83-IOM12E: (SAS)
Element Status Status Bytes Status Descriptions
1 [IOM12E A] : NONCRITICAL 03,09,00,20 SHELF ID DELTA, MASTER, RESERVED
2 [IOM12E B] : NONCRITICAL 03,01,00,20 SHELF ID DELTA, RESERVED