SAS Expander has set the Chassis LED ON
Applies to
- AFF A200
- FAS 2750
Issue
- System fault LED is amber on both nodes.
Example:
200::*> system controller service-event show
Node ID Event Location Event Description
---------------- --- ---------------------------------- ----------------------
A200-01 1 Chassis 1 SAS Expander has set the Chassis LED ON
A200-02 1 Chassis 1 SAS Expander has set the Chassis LED ON
- Module A/B Expander Temp shows failed.
Example:
A200::*> system node environment sensors show
Node Sensor State Value/Units Crit-Low Warn-Low Warn-Hi Crit-Hi
---- --------------------- ------ ----------- -------- -------- ------- -------
A200-01
CPU0 Temp Margin
init-failed
- C - - 0 -1
CPU0 Core Temp normal
38 C 0 5 90 100
PCM_Inlet_Temp normal
28 C 0 5 67 72
A200-02
PSU2 FRU normal
GOOD
PSU1 FRU normal
GOOD
SP Status normal
IPMI_HB_OK
Partner Status
not-available
PSU1 Present
not-available
PSU1 5V
not-available
- mV - - - -
PSU1 12V
not-available
- mV - - - -
PSU1 5V Curr
not-available
- mA - - - -
PSU1 12V Curr
not-available
- mA - - - -
PSU1 Fan 1
not-available
- RPM - - - -
PSU1 Fan 2
not-available
- RPM - - - -
PSU1 Inlet Temp
not-available
- C 0 5 57 62
PSU1 Hotspot Temp
not-available
- C 0 5 90 100
PSU2 Present
not-available
PSU2 5V
not-available
- mV - - - -
PSU2 12V
not-available
- mV - - - -
PSU2 5V Curr
not-available
- mA - - - -
PSU2 12V Curr
not-available
- mA - - - -
PSU2 Fan 1
not-available
- RPM - - - -
PSU2 Fan 2
not-available
- RPM - - - -
PSU2 Inlet Temp
not-available
- C 0 5 57 62
PSU2 Hotspot Temp
not-available
- C 0 5 90 100
PSU_FAN
not-available
Module B Expander Temp
failed
- C 0 5 80 90
Module A Expander Temp
failed
- C 0 5 80 90
Midplane 4 Temp failed
- C 0 5 55 60
Midplane 3 Temp failed
- C 0 5 55 60
Midplane 2 Temp failed
- C 0 5 55 60
Midplane 1 Temp failed
- C 0 5 55 60
Ambient Temp failed
- C 0 5 47 52