Post IOXM maintenance in FAS or AFF 80x0 models the IOXM power shows as bad
Applies to
- AFF8060
- AFF8080
- FAS8060
- FAS8080
- ONTAP 9
- Data ONTAP 8 7-Mode
Issue
The models listed in the applies to section, have the option of a dual chassis configuration as seen in Hardware Universe. This configuration is also known as a Chassis/IOXM configuration or abbreviated as CI. When a PCIe card is replaced in an IOXM module or the entire IOXM module is replaced, after giveback of the impaired node the IOXM power might show as bad and the HA interconnect ports as down:
cluster1::> system controller ioxm show
Node Display Name Is-Present? Power Status
------------- ------------ ----------- --------- ------
cluster1-01
cluster1-01/IOXM
present bad ok
cluster1-02
cluster1-02/IOXM
present good ok
cluster1::> system controller config show
.....
IOXM Status: present
Power: BAD
.....
Interconnect Port 1:
Port Name: ib0a
Default GID: fe80:0000:0000:0000:00a0:9800:0035:5850
Base LID: 0x850
Active MTU: 4096
Data Rate: 40 Gb/s (4X) QDR
Link State: DOWN
Interconnect Port 2:
Port Name: ib0b
Default GID: fe80:0000:0000:0000:00a0:9800:0035:5851
Base LID: 0x851
Active MTU: 4096
Data Rate: 40 Gb/s (4X) QDR
Link State: DOWN