Node reboots due to "Power Fail" error
- Views:
- 978
- Visibility:
- Public
- Votes:
- 0
- Category:
- fas-systems
- Specialty:
- hw
- Last Updated:
- 11/13/2024, 4:38:51 AM
Applies to
- AFF-A300 / FAS8200 or FAS2620 / FAS2650
- FAS2720 / FAS2750
- AFF-A220
Issue
- Node console or
SP/BMC> system log
output, shows that node reboots due to "Power Fail" error.
Example (reboot):
****************************
* Power Fail - Please Wait *
****************************
...
Destage is in progress, please wait
..........................................
Destage is completed successfully
Powering off from the backup power source
:
Waiting for giveback...(Press Ctrl-C to abort wait)
Example (boot loop):
****************************
* Power Fail - Please Wait *
****************************
...
Destage is in progress, please wait
..........................................
Destage is completed successfully
Powering off from the backup power source
BIOS Version: 11.2.1
Portions Copyright (C) 2014-2018 NetApp, Inc. All Rights Reserved.
...
Initializing System Memory ...
Loading Device Drivers ...
BIOS Version: 11.2.1
Portions Copyright (C) 2014-2018 NetApp, Inc. All Rights Reserved.
Initializing System Memory ...
Loading Device Drivers ...
- Node
SP/BMC events all
reporting:
Record 1234: Mon Jan 1 00:01:01 2024 [SP.emergency]: System input power lost
Record 2345: Mon Jan 1 00:10:10 2024 [SP.emergency]: System input power lost
- No other power alerts are reported by any Power Supply Unit (PSU), Power Distribution Unit (PDU) or any other Data Center electrical element (shelves, switches, etc.)