Skip to main content
NetApp Knowledge Base

Node Panic After Flash Cache NVMe Offline Alert

Views:
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

Applies to

  • AFF and FAS systems
  • ONTAP 9
  • FlashCache NVMe module X3311A

Issue

A node panic was observed on a FAS8300 system after a Flash Cache NVMe module went offline. The following log entries and symptoms were reported:

  • AutoSupport/EMS alert:
    FLNVME: HAGroupNotification from NELENASND01 (FlashCacheNVMeOffline) ALERT
  • sysconfig -a output:
    slot 1: Flash Cache NVMe
    Serial Number:      XXXXXXXX200281
            Part Number:        119-00329
            Hardware Revision:  A0
            Firmware Version:   NA03
            Model Name:         X3311A
            Capacity:           1024 GB
            State:              failed   
  • Node panic message:
    PANIC: prod/common/wafl/cleaner/wabe/wabe_bkt.c:8957: Assertion failure in SK process mpcleaner_thread1 on release 9.18.1P5(C)
  • After reboot, the Flash Cache NVMe module recovered and returned to an “ok” state.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.