Node Panic After Flash Cache NVMe Offline Alert
Applies to
- AFF and FAS systems
- ONTAP 9
- FlashCache NVMe module X3311A
Issue
A node panic was observed on a FAS8300 system after a Flash Cache NVMe module went offline. The following log entries and symptoms were reported:
- AutoSupport/EMS alert:
FLNVME: HAGroupNotification from NELENASND01 (FlashCacheNVMeOffline) ALERT - sysconfig -a output:
slot 1: Flash Cache NVMe
Serial Number: XXXXXXXX200281
Part Number: 119-00329
Hardware Revision: A0
Firmware Version: NA03
Model Name: X3311A
Capacity: 1024 GB
State: failed - Node panic message: