Node Missing Partner Disks After Power Loss on AFF-C250
Applies to
- NetApp AFF-C250
- ONTAP 9.13.1P10
Issue
- After a dirty shutdown caused by AC power loss, Node 02 in the cluster failed to boot properly and reported missing partner disks.
- Storage failover was not possible due to mailbox disk state being invalid.
::> storage failover show
Node Partner Takeover Possible State Description
-------------- -------------- ------- --------------------------------------------
Node1 Node2 true Connected to Node2. Waiting for cluster applications to come online on the local node.
Node2 - false Connected to partner, Partial giveback, Takeover is not possible: Storage failover mailbox disk state is invalid, Local node missing partner disks
2 entries were displayed.
- Node 02 has lost one mailbox disk from
storage failover mailbox-disk show