Issue

  • Recieving NoPathToNSM alerts when system is cabled in fully suppoted configuration.
  • Multiple nodes are reported in the health alerts.
  • NSM A and NSM B are both reported.
  • All cables are in the correct ports for the platform.
  • No issues seen over the physical connection to the switches.
  • EMS logs will have spam the message from the node with the cshm and call out both NSMs, may throttle the heath monitoring process:

Wed Oct 22 06:24:44 -0600 [locfs1-2a: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process nchm: NoPathToNSMB_Alert[5806924427062452224].
Wed Oct 22 06:24:44 -0600 [locfs1-2a: notifyd: asup.throttle.drop:notice]: Too many AutoSupport messages in too short a time, throttling AutoSupport: HA Group Notification from locfs1-2a (Health Monitor process nchm: NoPathToNSMB_Alert[5806924427062452224]) ALERT
Wed Oct 22 06:39:44 -0600 [locfs1-2a: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process nchm: NoPathToNSMA_Alert[8217768597705498624].
Wed Oct 22 06:54:44 -0600 [locfs1-2a: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process nchm: NoPathToNSMB_Alert[6325119859186769920].
Wed Oct 22 07:39:45 -0600 [locfs1-2a: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process nchm: NoPathToNSMB_Alert[5806924427062452224].

  • Alerts appear as the following:
cluster::> system health alert show
               Node: node-a
           Alert ID: NoPathToNSMA_Alert
           Resource: Shelf 7.11
           Severity: Major
    Indication Time: Wed Oct 08 09:09:17 2025
           Suppress: false
        Acknowledge: false
     Probable Cause: Controller node-a is connected only to module B of
                     shelf 7.11 through port e4a.
    Possible Effect: You will lose access to shelf 7.11 if module B fails.
Corrective Actions: 1. Consult the guide applicable to your NVMe storage shelf to review cabling rules for your system.
                     2. Connect controller node-a to module A and module
                     B of shelf 7.11.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.