  • ONTAP 9
  • X4013 Drive

Issue

  • Repeated panics

PANIC: page fault (supervisor read data, page not present) on VA 0xd8 cs:rip 0x20:0xffffffff8c3b87ab rflags 0x10286 in SK process wafl_exempt2


PANIC: A potential in-memory corruption of file system metadata (public inode 96, level 1, fbn 1704801990, incremental checksum mismatch) has been detected. Rebooting the node to keep the file system on disk unaffected. Contact NetApp technical support for help. in SK process wafl_exempt17


PANIC: wafl_load_buf: wip = 0x0xfffff840be4c8480, fbn = 2251731920, level = 1, last logical block = 84645, last physical block = 84645, flags = 0, in SK process wafl_exempt08

  • Disk errors leading to the panic

Sat Apr 10 11:30:27 +0000 [node-01: scsi_cmdblk_strthr_admin: scsi.cmd.checkCondition:error]: Disk device 0n.20L0: Check Condition: CDB 0x28:45d52998:0001: Sense Data SCSI:aborted command -  (0xb - 0x90 0x6 0xfa)(11099).

Sat Apr 10 11:30:27 +0000 [node-01: scsi_cmdblk_strthr_admin: scsi.cmd.aborted:error]: Disk device 0n.20L0: Command aborted: cdb 0x28:45d52998:0001 (11099).

Sat Apr 10 11:30:27 +0000 [node-01: disk_server_0: disk.IO.status:debug]: params: {'deviceName': '0n.20', 'returnCode': '9', 'pathRetryCount': '0', 'adapterStatus': '0x0', 'cdb': '0x28:45d52998:0001', 'basicTimeout': '5', 'iASCQ': '0x6', 'iSenseKey': '0xb', 'sSenseCode': '', 'ETime': '11101', 'iASC': '0x90', 'victimRetryCount': '0', 'sSenseKey': 'SCSI:aborted command', 'targetStatus': '0x2', 'disk_information': 'Disk 0n.20 Shelf 0 Bay 20 [NETAPP   X4013S172B7T6NTE NA56] S/N [xxxxxxxxxxx] UID [34393030:4D601317:00253859:00000004:00000000:00000000:00000000:00000000:00000000:00000000]', 'retryCount': '0', 'pathsTried': '0', 'timeoutRetryCount': '0'}
 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.