NS224 missing from system with no activity lights on drives
Applies to
- ONTAP 9
- NS224
Issue
- A power maintenance activity in the DC can result in the below scenarios
- NS224 shelf missing from system.
- No activity lights appear on disks on front of shelf.
- No light appears on shelf id.
- NSM modules have green LED indicators.
- PSU modules have green LED indicators.
- Yellow/amber light can be seen coming from inside the chassis (not on the NSM or PSU modules).
- Few aggregates state is unknown and their respective volumes in offline state
- Takeover Giveback of node does not help
- Shelf does not appear in any of the following commands:
::> storage port show
::> storage shelf sho
::> system node run -node * -command sysconfig -a
::> storage disk show -fields diskpathname
::> event log show -event *shelf*