NS224 NSM100 Module boot device NONCRITICAL fault
Applies to
- NS224 shelf
- NSM100 shelf module
Issue
- EMS logs report shelf fault and raise health alert:
[cluster-01: statd: monitor.shelf.warning:error]: Fault reported on disk storage shelf attached to channel 0x. Check fans, power supplies, disks, and temperature sensors.
[cluster-01: nchmd: hm.alert.raised:alert]: Alert Id = NoPathToNSMB_Alert , Alerting Resource = 12345678901234567890 raised by monitor node-connect
- Shelf module reports boot device fault in storage show fault -vcommand output (orSTORAGE-FAULTAutoSupport section:
Enclosure Status: normal
Channel: 0x
Shelf: 1
Shelf Type: NS224NSM100
Module Type: NSM100
Enclosure:
Element Status         Status Bytes  Status Descriptions
  1: OK                01,00,02,00   FAIL
Boot Device:
Element Status                      Status Bytes  Status Descriptions
  1 [NSM100 A]    : OK                01,00,00,00   
  2 [NSM100 B]    : NONCRITICAL       03,00,00,00  
- The Boot device error is visible through the storage shelf show -instancecommand.
Boot Devices:
 ID Mod Type         Size Status
--- --- ---------- ------ ------------
  1  A  SATA SSD    111GB normal
  2  B  SATA SSD    111GB error