Multiple disks not responding due to SAS adapter communication issue
Applies to
- FAS systems
Issue
- Multiple disks generate the following alert
[Node-01: config_thread: raid.config.filesystem.disk.not.responding:notice]: File system Disk /aggr0/plex0/rg0/0c.10.0 Shelf 10 Drawer 1 Slot 0 Bay 0 [NETAPP X377_STATE10TA07 NA00] S/N [ZA2ABN73] UID [5000C500:A782C9F7:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] is not responding.
[Node-01: config_thread: raid.config.filesystem.disk.not.responding:notice]: File system Disk /aggr1/plex0/rg0/0b.11.5 Shelf 11 Drawer 1 Slot 5 Bay 5 [NETAPP X377_STATE10TA07 NA00] S/N [ZA2AC11B] UID [5000C500:A7839157:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] is not responding.
[Node-01: config_thread: raid.config.filesystem.disk.not.responding:notice]: File system Disk /aggr2/plex0/rg1/0b.12.22 Shelf 12 Drawer 2 Slot 10 Bay 22 [NETAPP X377_STATE10TA07 NA00] S/N [ZA2ABN07] UID [5000C500:A77FCF57:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] is not responding.
- Disks appear as 'not responding' in
sysconfig -r
Broken disks
RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks)
--------- ------ ------------- ---- ---- ---- ----- -------------- --------------
not responding 0b.11.5 0b 11 5 SA:B 0 FSAS 7200 9324290/19096145920 9342976/19134414848
not responding 0b.12.2 0b 12 2 SA:B 0 FSAS 7200 9324290/19096145920 9342976/19134414848
not responding 0b.12.22 0b 12 22 SA:B 0 FSAS 7200 9324290/19096145920 9342976/19134414848
not responding 0b.12.26 0b 12 26 SA:B 0 FSAS 7200 9324290/19096145920 9342976/19134414848
not responding 0c.10.0 0c 10 0 SA:A 0 FSAS 7200 9324290/19096145920 9342976/19134414848