Multiple Disks Missing and DS460 Drawer Critical/Critical
Applies to
- DS460C
- HA Group Notification from ClusterA-01 (MULTIPLE DISKS MISSING) ERROR
Event Summary
Multiple Disks Missing AutoSupport messages are reported after a shelf drawer enters a Critical/Critical state.
This can also be accompanied by degraded or offline aggregates depending on how the impacted drives are allocated across raid groups.
Validate
- Check the current status of the Shelf Drawers:
- AutoSupport Section: STORAGE-SHELF-DRAWER.XML
- CLI Command:
Cluster::> storage shelf drawer show
Drawer Shelf Drawer Status A/B Closed? Count Firmware A/B------- ----- ----------------- ------------ ----------------1.10 1 critical/critical closed 12/...
- Check the status of aggregates:
- AutoSupport Section: AGGR-INFO.XML (check RAID Status for degraded, failed or reconstructing)
- CLI Command:
Cluster::> aggr show
Aggregate Size Available Used% State #Vols Nodes RAID Status--------- -------- --------- ----- ------- ------ ---------------- ------------aggr0_ClusterA-01 1.40TB 69.36GB 95% online 1 ClusterA-01 raid_dp, normalaggr0_ClusterA-02 1.40TB 69.36GB 95% online 1 ClusterA-02 raid_dp, normalaggr1_ClusterA-01 4.41TB 4.41TB 33% online 2 ClusterA-01 raid_tec, degradedaggr2_ClusterA-01 4.41TB 4.41TB 58% online 22 ClusterA-01 raid_tec, reconstruct
Resolution
A drawer replacement may be required.
Additional Information
Add your text here.