Multi-Disk Error Causes Node to Reboot
Applies to
- All FAS and AFF models
- ONTAP 9
- V-Series/Flexarray Backend (non-FAS/AFF disks)
Issue
Multi disk panic causes a node to reboot. The following error messages are seen in EMS:
EMS Error Message:
Sat Sep 04 15:56:53 EDT [cluster-01: config_thread: raid.vol.failed:notice]: Aggregate aggr1: Failed due to multi-disk error.
Sat Sep 04 15:56:53 EDT [cluster-01: config_thread: callhome.fdsk.fault:error]: Call home for FILESYSTEM DISK FAILED Shelf -, Bay -, Model [VRAID], S/N [6006016015603C0044145347182DE8110]
Sat Sep 04 15:56:53 EDT [cluster-01: raid_disk_thread: raid.disk.unload.done:info]: Unload of Disk NanoFCS01B:34.126L26 Shelf - Bay - [DGC VRAID 0533] S/N [6006016015603C0044145347182DE811] UID [60060160:15603C00:44145347:182DE811:00000000:00000000:00000000:00000000:00000000:00000000] has completed successfully
Sat Sep 04 15:56:53 EDT [cluster-01: config_thread: cf.multidisk.fatalProblem:info]: Node encountered a multidisk error or other fatal error while waiting to be taken over. aggr1: raid volfsm, fatal disk error in RAID group with no parity disk. raid type raid0 Group name plex0/rg1 state NORMAL 1 disk failed in the group. Disk NanoFCS01B:34.126L26 Shelf - Bay - [DGC VRAID 0533] S/N [6006016015603C0044145347182DE811] UID [60060160:15603C00:44145347:182DE811:00000000:00000000:00000000:00000000:00000000:00000000] error fatal disk error..