Skip to main content
NetApp Knowledge Base

Missing one disk from one specific sas adapter in "sysconfig -a" output

Views:
223
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
HW
Last Updated:

Applies to

  • AFF / FAS
  • DS224C / DS224-12
  • ONTAP  9

Issue

  • SYSCONFIG -A shows a shelf 11 bay 7 disk missing from sas adapter 0d.

    slot 0: SAS Host Adapter 0d (Broadcom SAS3616W rev. 2, SAS, <UP>)
        Firmware rev:      12.00.00.00
        NVDATA rev:        12.03.01.03
        Base WWN:          X:XXXXXX:XXXXXXX:XX
        Temperature:       Not Available
        Phy State:         [0] Enabled, 12.0 Gb/s
                           [1] Enabled, 12.0 Gb/s
                           [2] Enabled, 12.0 Gb/s
                           [3] Enabled, 12.0 Gb/s 


        11.6 : NETAPP   X371_S164A960ATE NA53 915.4GB 520B/sect (AAAAAAAAAAAAAA)
        11.8 : NETAPP   X371_S164A960ATE NA53 915.4GB 520B/sect (CCCCCCCCCCCCCC)

 

  • AutoSupport alert received:

HA Group Notification from cluster-01 (DISK REDUNDANCY FAILED) ERROR

  • sas adapter 0a shows on shelf 11 bay 7 disk.

slot 0: SAS Host Adapter 0a (Broadcom SAS3616W rev. 2, SAS, <UP>)
        Firmware rev:      12.00.00.00
        NVDATA rev:        12.03.01.03
        Base WWN:          X:XXXXXX:XXXXXXX:XX
        Temperature:       Not Available
        Phy State:         [0] Enabled, 12.0 Gb/s
                           [1] Enabled, 12.0 Gb/s
                           [2] Enabled, 12.0 Gb/s
                           [3] Enabled, 12.0 Gb/s
        Mini-SAS HD Vendor:        Molex Inc.
        Mini-SAS HD Part Number:   112-00437+A0
        Mini-SAS HD Type:          Passive Copper (unequalized) 2m end_0
        Mini-SAS HD Serial Number: 132331677         


        11.6 : NETAPP   X371_S164A960ATE NA53 915.4GB 520B/sect (AAAAAAAAAAAAAA)
        11.7 : NETAPP   X371_S164A960ATE NA53 915.4GB 520B/sect (BBBBBBBBBBBBBB)
        11.8 : NETAPP   X371_S164A960ATE NA53 915.4GB 520B/sect (CCCCCCCCCCCCCC) 

 

  • SYSCONFIG -R show issued disk is recognized and working nomally.

    RAID group /aggr_data_dis_mnas_10_SAS_01/plex0/rg4 (normal, block checksums)

      RAID Disk    Device      HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Phys (MB/blks)
      ---------    ------      ------------- ---- ---- ---- ----- --------------    --------------
      dparity     0a.11.9P1    0a    11  9   SA:A   0   SSD   N/A 228853/468690944  228861/468707328 
      parity      0a.11.17P1    0a    11  17  SA:A   0   SSD   N/A 228853/468690944  228861/468707328 
      data        0d.11.16P1    0d    11  16  SA:B   0   SSD   N/A 228853/468690944  228861/468707328 
      data        0a.11.15P1    0a    11  15  SA:A   0   SSD   N/A 228853/468690944  228861/468707328 
      data        0a.11.11P1    0a    11  11  SA:A   0   SSD   N/A 228853/468690944  228861/468707328 
      data        0d.11.12P1    0d    11  12  SA:B   0   SSD   N/A 228853/468690944  228861/468707328 
      data        0d.11.8P1    0d    11  8   SA:B   0   SSD   N/A 228853/468690944  228861/468707328 
      data        0d.11.10P1    0d    11  10  SA:B   0   SSD   N/A 228853/468690944  228861/468707328 
      data        0a.11.19P1    0a    11  19  SA:A   0   SSD   N/A 228853/468690944  228861/468707328 
      data        0a.11.13P1    0a    11  13  SA:A   0   SSD   N/A 228853/468690944  228861/468707328 
      data        0d.11.14P1    0d    11  14  SA:B   0   SSD   N/A 228853/468690944  228861/468707328 
      data        0d.11.18P1    0d    11  18  SA:B   0   SSD   N/A 228853/468690944  228861/468707328 
      data        0a.11.7P1    0a    11  7   SA:A   0   SSD   N/A 228853/468690944  228861/468707328 
      data        0d.11.6P1    0d    11  6   SA:B   0   SSD   N/A 228853/468690944  228861/468707328 

    RAID group /aggr_data_dis_mnas_10_SAS_01/plex0/rg5 (normal, block checksums)

      RAID Disk    Device      HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Phys (MB/blks)
      ---------    ------      ------------- ---- ---- ---- ----- --------------    --------------
      dparity     0a.11.9P2    0a    11  9   SA:A   0   SSD   N/A 228853/468690944  228861/468707328 
      parity      0a.11.17P2    0a    11  17  SA:A   0   SSD   N/A 228853/468690944  228861/468707328 
      data        0d.11.16P2    0d    11  16  SA:B   0   SSD   N/A 228853/468690944  228861/468707328 
      data        0a.11.15P2    0a    11  15  SA:A   0   SSD   N/A 228853/468690944  228861/468707328 
      data        0a.11.11P2    0a    11  11  SA:A   0   SSD   N/A 228853/468690944  228861/468707328 
      data        0d.11.12P2    0d    11  12  SA:B   0   SSD   N/A 228853/468690944  228861/468707328 
      data        0d.11.8P2    0d    11  8   SA:B   0   SSD   N/A 228853/468690944  228861/468707328 
      data        0d.11.10P2    0d    11  10  SA:B   0   SSD   N/A 228853/468690944  228861/468707328 
      data        0a.11.19P2    0a    11  19  SA:A   0   SSD   N/A 228853/468690944  228861/468707328 
      data        0a.11.13P2    0a    11  13  SA:A   0   SSD   N/A 228853/468690944  228861/468707328 
      data        0d.11.14P2    0d    11  14  SA:B   0   SSD   N/A 228853/468690944  228861/468707328 
      data        0d.11.18P2    0d    11  18  SA:B   0   SSD   N/A 228853/468690944  228861/468707328 
      data        0a.11.7P2    0a    11  7   SA:A   0   SSD   N/A 228853/468690944  228861/468707328 
      data        0d.11.6P2    0d    11  6   SA:B   0   SSD   N/A 228853/468690944  228861/468707328

  • From the STORAGE EXPANDER, the Partial Rate for DIS/INVWD status is NA for disks in Shell 11 Bay 7.

Shelf name:    0d.shelf11
Shelf id:      11
Channel:       0d
Module:        B
Shelf UID:     XX:XX:XX:XX:XX:XX:XX:XX
Shelf S/N:     XXXXXXXXXXXXXX
Term switch:   N/A
Shelf state:   ONLINE
Module state:  OK                      Partial Path   Link    Invalid   Running     Loss    Phy       CRC     Phy
Disk          Port   Timeout        Rate     DWord    Disparity   Dword   Reset     Error   Change
Id           State   Value (ms)    (Gb/s)    Count    Count       Count   Problem   Count   Count
-------------------------------------------------------------------------------------------------- 

[  6       ] OK             7       12.0        0           0       0        0         0       1
[  7       ] DIS/INVWD      7         NA      484         478       0        0         0       2   
[  8       ] OK             7       12.0        0           0       0        0         0       1

  • ENCLOSURE BYPASSED can be found in storage show fault.

> storage show fault

Enclosure Status: non-critical
Channel: 0a
Shelf: 0
Shelf Type: DS212-12
Product Serial Number: 792131000345
Module Type: IOM12E

Disk Elements:

Element Status                  Status Bytes  Status Descriptions

  0 [Bay  0]: NONCRITICAL       03,00,20,28   ENCLOSURE BYPASSED A, BYPASSED A, FAULT REQSTD
  1 [Bay  1]: OK                01,01,00,00   
  2 [Bay  2]: OK                01,02,00,00   
  3 [Bay  3]: OK                01,03,00,00   
  4 [Bay  4]: OK                01,04,00,00   
  5 [Bay  5]: OK                01,05,00,00  

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.