Skip to main content
NetApp Knowledge Base

LIF is operationally down after unjoin the node

Views:
555
Visibility:
Public
Votes:
1
Category:
not set
Specialty:
san
Last Updated:

Applies to

  • SAN
  • ONTAP 9
  • iSCSI

Issue

  • iSCSI LIF is down and unable to bring up after node unjoin/rejoin(node replacement)

::> net int show
  (network interface show)
            Logical    Status     Network            Current       Current Is
Vserver     Interface  Admin/Oper Address/Mask       Node          Port    Home
----------- ---------- ---------- ------------------ ------------- ------- ----
ISCSI
            iscsi_LIF  up/down  10.10.xx.xxx/24    NetApp  e0c     true
            

Info: Configuration details for LIF were successfully applied, but an error was encountered while updating the iSCSI target. Use the "vserver iscsi
interface show" to review the iSCSI status of the LIF. If necessary, wait a few minutes for the update to take effect.

  • ESXi

2020-08-04T11:27:40Z iscsid: cannot make a connection to 10.10.xx.xxx:3260 (112,Host is down)


2020-08-04T08:19:31.722Z cpu13:2314298)VMW_SATP_ALUA: satp_alua_issueCommandOnPath:735: Path "vmhba64:C11:T1:L6" (DOWN) command 0xa3 failed with status Timeout. H:0x5 D:0x0 P:0x0 Invalid sense data: 0x0 0x0 0x0.
2020-08-04T08:19:31.722Z cpu13:2314299)VMW_SATP_ALUA: satp_alua_issueCommandOnPath:735: Path "vmhba64:C11:T1:L7" (DOWN) command 0xa3 failed with status Timeout. H:0x5 D:0x0 P:0x0 Invalid sense data: 0x0 0x0 0x0.
2020-08-04T08:19:33.705Z cpu24:2314304)VMW_SATP_ALUA: satp_alua_issueCommandOnPath:735: Path "vmhba64:C11:T1:L0" (DOWN) command 0xa3 failed with status Timeout. H:0x5 D:0x0 P:0x0 Invalid sense data: 0x0 0x0 0x0.
2020-08-04T08:19:33.711Z cpu0:2314303)VMW_SATP_ALUA: satp_alua_issueCommandOnPath:735: Path "vmhba64:C11:T1:L1" (DOWN) command 0xa3 failed with status Timeout. H:0x5 D:0x0 P:0x0 Invalid sense data: 0x0 0x0 0x0.
2020-08-04T08:19:3

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.