Interconnect down on Fabric Metrocluster during setup
Applies to
- FAS 8200
- 4 node Fabric Metrocluster
Issue
- During setup, storage failover cannot be enabled due to the HA interconnect being down
cluster::> storage failover show
Takeover
Node Partner Possible State Description
-------------- -------------- -------- -------------------------------------
node-01 node-02 false Waiting for node-02, Takeover
is not possible: Storage failover
interconnect error, NVRAM log not
synchronized
node-02 node-01 false Waiting for node-01, Takeover
is not possible: Storage failover
interconnect error, NVRAM log not
synchronized
2 entries were displayed.
- Interconnect physical link is up, but RDMA is down
cluster::>set advanced
cluster::*>interconnect status show
(system ha interconnect status show)
Node: node-01
Link Status: up
IC RDMA Connection: down
Node: node-02
Link Status: up
IC RDMA Connection: down
2 entries were displayed.
metrocluster setup
has already been run