In Errors Count from cluster port seen on Cluster switch
- Views:
- 149
- Visibility:
- Public
- Votes:
- 0
- Category:
- fas-systems
- Specialty:
- HW
- Last Updated:
- 11/4/2022, 12:49:30 PM
Applies to
- FAS8200
- CN1610
Issue
- In Errors Count from cluster port seen on Cluster switch resulting in performance issue
Switch Name: Clus-switch1
Switch Type: cluster-network
Interface name: Slot: 0 Port: 4 10G - Level
In Error Count: 195241906
In Ucast Packet Count: 1898860469
In Non-Ucast Packet Count: 417863
In Error %: 2
In Error % (Conv int): 235
In Error % (decimal): 2.353582422295592 << -----------
Out Error Count: 0
Out Ucast Packet Count: 714261296
Out Non-Ucast Packet Count: 5347101
Out Error %: 0
Out Error % (Conv Int): 0
Out Error % (decimal): 0
In warning Count: 2
Out warning Count: 0
- Cluster LIF reports as flapping in EMS log
[Node01: vifmgr: vifmgr.port.monitor.failed:error]: The "link_flapping" health check for port e0b (node Node01) has failed. The port is operating in a degraded state.