How to troubleshoot a raid volfsm, fatal multi-disk error panic
Applies to
- ONTAP 9
- ONTAP Select
- AFF System
- ASA System
- FAS System
- Panic String: aggr aggr1: raid volfsm, fatal multi-disk error.
Description
A node panic containing the string “raid volfsm, fatal multi-disk error
” indicates that an aggregate has failed due to losing more drives than can be handled by the raid level protection in use:
RAID Type | Survivable drive failures |
---|---|
raid0 | 0 |
raid4 | 1 |
raid_dp | 2 |
raid_tec | 3 |
- Example Panic strings
-
Panic String: aggr aggr1: raid volfsm, fatal disk error in RAID group with no parity disk..
Panic String: aggr aggr1: raid volfsm, fatal multi-disk error.. Primary Tier: Raid type - raid_tec Group name plex0/rg0 state NORMAL. 21 disks failed in the group.
Panic String: aggr aggr1: raid volfsm, fatal multi-disk error.. Cache Tier: Raid type - raid4 Group name plex0/rg2 state NORMAL. 3 disks failed in the group.
Panic String: aggr aggr1: raid volfsm, fatal multi-disk error.. Raid type - raid0, mirrored Group name plex0/rg0 state NORMAL. 1 disk failed in the group.
Panic String: aggr aggr1: raid volfsm, fatal multi-disk error.. Raid type - raid_dp Group name plex0/rg0 state NORMAL. 3 disks failed in the group.
Panic String: aggr aggr1: raid volfsm, fatal multi-disk error. raid type raid_dp Group name plex0/rg6 state NORMAL 7 disks failed in the group.
Panic String: aggr aggr1: raid volfsm, fatal multi-disk error.. Raid type - raid_dp Group name plex0/rg0 state DIRTY. 10 disks failed in the group.
Panic String: aggr aggr1: raid volfsm, fatal multi-disk error.. Raid type - raid_dp, mirrored Group name plex0/rg0 state DEGRADEDRECONS. 4 disks failed in the group.
Panic String: aggr aggr1: raid volfsm, fatal multi-disk error.. Raid type - raid4, mirrored Group name plex0/rg0 state NORMAL. 2 disks failed in the group.
Panic String: aggr aggr1: raid volfsm, fatal multi-disk error.. Raid type - raid_tec Group name plex0/rg0 state NORMAL. 6 disks failed in the group.
Panic message will indicate