How to determine whether the SFP or Cable is faulty on a Brocade switch
Applies to
Brocade
Description
- How to determine SFP or cable faulty, review the
porterrshow
output from the switch.enc out
errors alone imply primarily a cable issue.enc out
andcrc err
in combination primarily imply a GBIC/SFP problem.disc c3
combined withc3 timeout tx