How to determine AFF A900, ASA A900 or FAS9500 PSU power and efficiency
Applies to
- AFF A900, ASA A900, AFF A700
- FAS9500, FAS9000
- 80 PLUS® Platinum 1600W PSU
- 80 PLUS® Titanium 2000W PSU
Description
- This KB article helps you determine the correct part to order when replacing a power supply unit (PSU) in AFF A900, ASA A900, AFF A700, FAS9500 or FAS9000 systems
- Current 1600-Watt (W) PSUs of NetApp AFF A900, ASA A900, AFF A700, FAS9500 and FAS9000 storage systems are certified at 80 PLUS Platinum efficiency
- Effective 2024-01-01, Commission Regulation (EU) 2019/424 requires power supplies for certain classes of storage equipment to meet the 80 PLUS Titanium efficiency requirement
- NetApp 80 PLUS Titanium 2000W PSUs for these models are now available, identified by a blue LED icon label.
- Currently available PSU options:
Part Number |
Part Description |
Mfg. Part Number |
Vendor + Model |
80 PLUS Efficiency |
X97600A |
Power Supply,1600W |
114-00146 |
Delta DPS-1600AB-4 |
Platinum |
X97603A |
Power Supply,2000W Titanium |
114-00216 |
Delta TDPS-2000KB |
Titanium |
IMPORTANT: Intermixing PSUs with different power ratings and efficiencies in the same chassis is not supported. When replacing a PSU, the correct part must be used or damage to the system might occur. |