How to determine 1600W PSU power efficiency
Applies to
- AFF A800, AFF A400, AFF A250
 - AFF C800, AFF C400, AFF C250
 - ASA A800, ASA A400, ASA A250
 - ASA C800, ASA C400, ASA C250
 - FAS8700, FAS8300
 - NS224 storage shelf
 - E-Series EF600, EF300
 - 80 PLUS® Platinum 1600W PSU
 - 80 PLUS® Titanium 1600W PSU
 
Description
This KB article helps you determine the correct part to order when replacing a 1600-Watt power supply unit (PSU) in some NetApp products:
- Current 1600-Watt (W) PSUs of NetApp AFF, ASA, FAS and E-Series storage systems are certified at 80 PLUS Platinum efficiency
 - Effective 2024-01-01, Commission Regulation (EU) 2019/424 requires power supplies for certain classes of storage equipment to meet the 80 PLUS Titanium efficiency requirement
 - NetApp 80 PLUS Titanium 1600W PSUs are now available
 - NetApp leverages multiple suppliers for a given Mfg. part number and power efficiency
 
Currently available PSU options:
| 
             Part Number  | 
            
             Part Description  | 
            
             Mfg. Part Number  | 
            
             Vendor + Model  | 
            
             80 PLUS Efficiency  | 
        
|---|---|---|---|---|
| 
             X737A X736A  | 
            
             PSU,AFF A700s,A800,EF600,EF300 PSU,AFF A700s,A800,A320  | 
            
             114-00208  | 
            
             Delta DPS-1600AB-18  | 
            
             Platinum  | 
        
| 
             X97602A  | 
            
             Power Supply,1600W,Titanium  | 
            
             114-00217  | 
            
             Delta TDPS-1600GB  | 
            
             Titanium  | 
        
| IMPORTANT: Intermixing PSUs with different efficiencies in the same chassis is not supported. When replacing a PSU, the correct part must be used or damage to the system might occur. | ||||