  • CN1610 cluster network switch

Issue

  • Asup logs:  Ems-log-file.gz

[node2: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process cshm: ClusterIfIslDownWarn_Alert [clustersw1. Link Aggregate 1].ALERT
[node2: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process cshm: ClusterIfIslDownWarn_Alert [clustersw1. Link Aggregate 1].ALERT
[node2: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process cshm: ClusterIfIslDownWarn_Alert [clustersw1. Link Aggregate 1].ALERT
[node2: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process cshm: ClusterIfIslDownWarn_Alert [clustersw1. Link Aggregate 1].ALERT

 
  • Asup log:  cluster-switch-interface.xml     

        Interface Display Name- link Aggregate 1 
        Port Config Status - degraded 

  • Port channel not configured on both switches:
    Switch logs:

      show port-channel all

      *************** show port-channel all ***************
   Log.    Channel                     Adm.      Mbr    Device/       Port      Port
    Intf    Name            Min  Link   Mode Type Ports  Timeout       Speed     Active
    ------- --------------- ---- ------ ---- ---- ------ ------------- --------- -------
    3/1     ch1             1    Down   En.  Stat
    3/2     ch2             1    Down   En.  Stat
    3/3     ch3             1    Down   En.  Stat
    3/4     ch4             1    Down   En.  Stat

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.