Skip to main content
NetApp Knowledge Base

Host lost connectivity to FC Lun during reboot or upgrade

Views:
326
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
san
Last Updated:

Applies to

  • FCP
  • ONTAP 9
  • VMware
  • Solaris cluster
  • VSI OpenVMS 8.4-2L1

Issue

  • Host lost access to FC lun during node reboot or takeover of node where lun was hosted.
  • The Affected wwpn is logged into single node as per the output of command- vserver fcp ping-initiator show -wwpn <wwpn> :

cluster::> vserver fcp ping-initiator show -wwpn 21:00:00:xx:xx:xx:xx:xx
                            Node       Logical   Ping        Extended
Vserver   WWPN              Name       Interface Status      Status
--------- ----------------- ---------- --------- ----------- -----------------
vserver_1
          21:00:00:xx:xx:xx:xx:xx n01 lfc001 reachable wwpn-logged-in
          21:00:00:xx:xx:xx:xx:xx n01 lfc002 not-zoned -
          21:00:00:xx:xx:xx:xx:xx n01 lfc003 not-zoned -
          21:00:00:xx:xx:xx:xx:xx n01 lfc004 not-zoned -
          21:00:00:xx:xx:xx:xx:xx n01 lfc005 reachable wwpn-logged-in
          21:00:00:xx:xx:xx:xx:xx n01 lfc006 not-zoned -
          21:00:00:xx:xx:xx:xx:xx n01 lfc007 not-zoned -
          21:00:00:xx:xx:xx:xx:xx n01 lfc008 not-zoned -
          21:00:00:xx:xx:xx:xx:xx n02 lfc009 not-zoned -
          21:00:00:xx:xx:xx:xx:xx n02 lfc010 not-zoned -
          21:00:00:xx:xx:xx:xx:xx n02 lfc011 not-zoned -
          21:00:00:xx:xx:xx:xx:xx n02 lfc012 not-zoned -
          21:00:00:xx:xx:xx:xx:xx n02 lfc013 not-zoned -
          21:00:00:xx:xx:xx:xx:xx n02 lfc014 not-zoned -
          21:00:00:xx:xx:xx:xx:xx n02 lfc015 not-zoned -
          21:00:00:xx:xx:xx:xx:xx n02 lfc016 not-zoned -
16 entries were displayed.

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.