HOST_PORT_FAIL occurs on AFF A700
Applies to
- Data ONTAP 8
- ONTAP 9
- AFF A700
Issue
- The following alert reports in EMS
HA Group Notification (HOST_PORT_FAIL - Disabled by IOM) ALERT- SAS port PHY
unknowninrun -node cluster_rf_01 2 sasadmin adapter_sa tate 10c.
cluster::> run -node cluster_01 2 sasadmin adapter_sa tate 10cState for adapter channel 10c: UP (degraded)Invald Disprt Loss Phy PhyDWord Error Sync Reset ChangePHY STATE Count Count Count Prob Count--------------------------------------------------------0 12.0 Gb/s 0 0 0 0 31 12.0 Gb/s 0 0 0 0 32 12.0 Gb/s 0 0 0 0 33 Rate unknown 0 0 0 0 4SAS port status
online-degraded in storage port show.cluster::> storage port showSpeed VLAN IsNode Port Type (Gb/s) StateStatus ID Dedicat------------------ ---- ----- ------ --------------- --------- ---- -------cluster_0110a SAS 12 enabled online - true10b SAS 12 enabled online - true10c SAS 12 enabled online - true10d SAS 12 enabled online - true1a SAS 12 enabled online - true1b SAS 12 enabled online - true1c SAS 12 enabled online - true1d SAS 12 enabled online - true9a SAS 12 enabled online - true9b SAS 12 enabled online - true9c SAS 12 enabled online - true9d SAS 12 enabled online - truecluster_0210a SAS 12 enabled online - true10b SAS 12 enabled online - true10c SAS 12 enabled online-degraded - true10d SAS 12 enabled online - true1a SAS 12 enabled online - true1b SAS 12 enabled online - true1c SAS 12 enabled online - true1d SAS 12 enabled online - true9a SAS 12 enabled online - true9b SAS 12 enabled online - true9c SAS 12 enabled online - true9d SAS 12 enabled online - true