  • Unexpected Takeover Event
    • Automatic case alert with "INTERNAL HALT"

Issue

  • Automatic case with AutoSupport alert message for "INTERNAL HALT". Example:

HA Group Notification from node_name (CONTROLLER TAKEOVER COMPLETE AUTOMATIC - INTERNAL HALT) ALERT

  • Internal halt initiated due to an environmental shutdown for multiple fan failures. Example:

... [node_name: env_mgr: monitor.chassisFan.stop:error]: Chassis fan contains at least one stopped fan: Sysfan1 F1 Speed (failed)
... [node_name: env_mgr: monitor.chassisFan.stop:error]: Chassis fan contains at least one stopped fan: Sysfan1 F2 Speed (failed)
... [node_name: env_mgr: monitor.chassisFan.stop:error]: Chassis fan contains at least one stopped fan: Sysfan2 F1 Speed (failed)
... [node_name: env_mgr: monitor.chassisFan.stop:error]: Chassis fan contains at least one stopped fan: Sysfan2 F2 Speed (failed)
... [node_name: env_mgr: monitor.chassisFan.stop:error]: Chassis fan contains at least one stopped fan: Sysfan3 F1 Speed (failed)
... [node_name: env_mgr: monitor.chassisFan.stop:error]: Chassis fan contains at least one stopped fan: Sysfan3 F2 Speed (failed)
... [node_name: env_mgr: monitor.chassisFan.stop:error]: Chassis fan contains at least one stopped fan: Sysfan4 F1 Speed (failed)
... [node_name: env_mgr: monitor.chassisFan.stop:error]: Chassis fan contains at least one stopped fan: Sysfan4 F2 Speed (failed)
... [node_name: env_mgr: monitor.chassisFan.stop:error]: Chassis fan contains at least one stopped fan: Sysfan5 F1 Speed (failed)
... [node_name: env_mgr: monitor.chassisFan.stop:error]: Chassis fan contains at least one stopped fan: Sysfan5 F2 Speed (failed)
... [node_name: env_mgr: monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Multiple chassis fans have failed.
... [node_name: statd: monitor.fan.failed:alert]: Multiple fans has failed: Sysfan1 F1, Sysfan1 F2, Sysfan2 F1, Sysfan2 F2, Sysfan3 F1, Sysfan3 F2, Sysfan4 F1, Sysfan4 F2, Sysfan5 F1, Sysfan5 F2.
... [node_name: monitor: monitor.globalStatus.critical:EMERGENCY]: Multiple fans has failed: Sysfan1 F1, Sysfan1 F2, Sysfan2 F1, Sysfan2 F2, Sysfan3 F1, Sysfan3 F2, Sysfan4 F1, Sysfan4 F2, Sysfan5 F1, Sysfan5 F2. Power Supply Status Critical: PSU1.
... [node_name: env_mgr: monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (Multiple fans failed)
... [node_name: shutdown_thread0: ha.localNodeShutDown:notice]: Shutdown of the local node has been initiated with inhibit_takeover set to FALSE.

  • ONTAP events report Chassis power is degraded: Power Supply Status Critical. Example:

::> event log show
... node   EMERGENCY   monitor.globalStatus.critical: Power Supply Status Critical: PSU1.
... node   ERROR       callhome.chassis.power: Call home for CHASSIS POWER DEGRADED: Power Supply Status Critical: PSU1.
... node   ALERT       monitor.chassisPower.degraded: Chassis power is degraded: Power Supply Status Critical: PSU1.
... node   ERROR       callhome.chassis.ps.degraded: Call home for CHASSIS POWER SUPPLY DEGRADED: PS 1

  • The issue remains after the power cord and PSU re-seat in the chassis
  • The issue follows  the PSU, when swapped with another working one.
  • The SP/BMC may report events for the PSU. Example:

BMC node_name> events all
...
Record 1303: Thu Sep 04 15:01:00.484212 2025 [IPMI.notice]: 0008 | 02 | EVT: 6f02ffff | PSU1_Status | Assertion Event, "Attention"

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.