Flashpool aggregate creation fails due to lack of unpartitioned SSDs
Applies to
- FAS 2750
- ONTAP 9
Issue
The addition of SSDs to an aggregate for flashpool implementation fails with the following error
cluster1::> storage aggregate add-disks -aggregate Aggr01 -diskcount 5 -disktype SSD -raidtype raid_dp
Error: command failed: Addition of disks failed for aggregate "Aggr01" on node "node-1". Reason: 5 disks are needed from Pool0, but no matching disks are available in that pool.