Skip to main content
NetApp Knowledge Base

FILESYSTEM DISK MISSING in DS460C drawer 4

Views:
5
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

Applies to

DS460C storage shelf

Issue

  • FILESYSTEM DISK MISSING message reported in AutoSupport

raid.config.filesystem.disk.missing:info]: File system Disk /aggr5_prjnas9001_data/plex0/rg1/10d.20.40 Shelf 20 Drawer 4 Slot 4 Bay 40 [NETAPP   X377_SCBPE10TA07 NA01] S/N [WP02MWNY] UID [UID] is missing.
callhome.fdsk.missing:error]: Call home for FILESYSTEM DISK MISSING

  • DISK REDUNDANCY FAILED event reported in AutoSupport

callhome.dsk.redun.fault:error]: Call home for DISK REDUNDANCY FAILED

  • Disk bay(PHY# 4) shows disabled/disabled state

cluster::*> storage shelf drawer show-slot phy
Shelf Drawer PHY #  Type     SAS Address         PHY State A/B
----- ------ -----  -------- ----------------- -----------------
1.20
           4
                 1  disk     5000c500fc1ea9e1   enabled/enabled
                 2  disk     5000c500fc1ef0cd   enabled/enabled
                 3  disk     5000c500fc1e6901   enabled/enabled
                 4  disk     5000c500fc215b0d  disabled/disabled
                 5  disk     5000c500fc1e6d15   enabled/enabled
                 6  disk     5000c500fc220a5d   enabled/enabled
                 7  disk     5000c500fc21f181   enabled/enabled
                 8  disk     5000c500fc215351   enabled/enabled
                 9  disk     5000c500fc1f734d   enabled/enabled
                10  disk     5000c500fc219371   enabled/enabled
                11  disk     5000c500fc21f031   enabled/enabled

  • Disk missing on both SAS paths (A and B)

STORAGE-FAULT
Enclosure Status: critical
Channel: 10d
Shelf: 20
Shelf Type: DS460-12
Product Serial Number: 952533000684
Module Type: IOM12B

Disk Elements:
Element Status                  Status Bytes  Status Descriptions
  0 [Bay  0]: OK                01,00,00,00
  1 [Bay  1]: OK                01,01,00,00
  …
39 [Bay  3]: OK                01,03,00,00
40 [Bay  4]: CRITICAL          02,04,00,0C   BYPASSED B, BYPASSED A
41 [Bay  5]: OK                01,05,00,00

  • Disk not detected after physical replacement

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.