FILESYSTEM DISK MISSING in DS460C drawer 4
Applies to
Issue
- FILESYSTEM DISK MISSING message reported in AutoSupport
raid.config.filesystem.disk.missing:info]: File system Disk /aggr5_prjnas9001_data/plex0/rg1/10d.20.40 Shelf 20 Drawer 4 Slot 4 Bay 40 [NETAPP X377_SCBPE10TA07 NA01] S/N [WP02MWNY] UID [UID] is missing.
callhome.fdsk.missing:error]: Call home for FILESYSTEM DISK MISSING
- DISK REDUNDANCY FAILED event reported in AutoSupport
callhome.dsk.redun.fault:error]: Call home for DISK REDUNDANCY FAILED
- Disk bay(PHY# 4) shows disabled/disabled state
cluster::*> storage shelf drawer show-slot phy
Shelf Drawer PHY # Type SAS Address PHY State A/B
----- ------ ----- -------- ----------------- -----------------
1.20
4
1 disk 5000c500fc1ea9e1 enabled/enabled
2 disk 5000c500fc1ef0cd enabled/enabled
3 disk 5000c500fc1e6901 enabled/enabled
4 disk 5000c500fc215b0d disabled/disabled
5 disk 5000c500fc1e6d15 enabled/enabled
6 disk 5000c500fc220a5d enabled/enabled
7 disk 5000c500fc21f181 enabled/enabled
8 disk 5000c500fc215351 enabled/enabled
9 disk 5000c500fc1f734d enabled/enabled
10 disk 5000c500fc219371 enabled/enabled
11 disk 5000c500fc21f031 enabled/enabled
- Disk missing on both SAS paths (A and B)
STORAGE-FAULTEnclosure Status: criticalChannel: 10dShelf: 20Shelf Type: DS460-12Product Serial Number: 952533000684Module Type: IOM12B
Disk Elements:Element Status Status Bytes Status Descriptions 0 [Bay 0]: OK 01,00,00,00 1 [Bay 1]: OK 01,01,00,00 …39 [Bay 3]: OK 01,03,00,0040 [Bay 4]: CRITICAL 02,04,00,0C BYPASSED B, BYPASSED A41 [Bay 5]: OK 01,05,00,00
- Disk not detected after physical replacement