FAS500f internal disk missing on one node
Applies to
- ONTAP 9
- FAS500f
Issue
- Single disk is missing from internal shelf of a FAS500f node.
slot 0: Virtual NVMe Host Adapter 0n 1 : NETAPP X4020S173A15TNQF NA54 14651.0GB 4160B/sect (XXXXXXXXXXXXXX) <<<< Bay 0 is missing 2 : NETAPP X4020S173A15TNQF NA54 14651.0GB 4160B/sect (XXXXXXXXXXXXXX) 3 : NETAPP X4020S173A15TNQF NA54 14651.0GB 4160B/sect (XXXXXXXXXXXXXX) 4 : NETAPP X4020S173A15TNQF NA54 14651.0GB 4160B/sect (XXXXXXXXXXXXXX)
- HA Group Notification (HA GROUP ERROR: DISK/SHELF COUNT MISMATCH) ERROR
- EMS log shows the disk going missing:
[Node-06: svc_queue_thread: cf.disk.inventory.mismatch:debug]: Status of the disk ?.? has recently changed or the node (Node-06) is missing the disk.
- Disk reseat/replace does not resolve the error.
- Swapping with a known good spare and the error stays with the same disk bay.
- Rebooting the node does not resolve the error.