FAS2820 Controller Shuts Down Due to NVMEM Battery Error
Applies to
Issue
- The FAS2820 controller experiences an unexpected shutdown.
- The system logs indicate multiple battery sensor failures, resulting in an emergency environmental shutdown:
Feb 26 14:46:06 [localhost:callhome.battery.failure:EMERGENCY]: Call home for BATTERY ('Bat Volt' unreadable) CRITICAL.Feb 26 14:46:07 [localhost:callhome.battery.failure:EMERGENCY]: Call home for BATTERY ('Bat Curr' unreadable) CRITICAL.Feb 26 14:46:07 [localhost:callhome.battery.failure:EMERGENCY]: Call home for BATTERY ('Bat Dstg Cycles' unreadable) CRITICAL.Feb 26 14:46:07 [localhost:callhome.battery.failure:EMERGENCY]: Call home for BATTERY ('Bat Charge Curr' unreadable) CRITICAL.Feb 26 14:46:08 [localhost:callhome.battery.failure:EMERGENCY]: Call home for BATTERY ('Bat Dcharge FET' unreadable) CRITICAL.Feb 26 14:46:49 [localhost:callhome.battery.failure:EMERGENCY]: Call home for BATTERY ('Bat Temp' unreadable) CRITICAL.Feb 26 14:46:49 [localhost:callhome.battery.failure:EMERGENCY]: Call home for BATTERY ('Bat Full Cap' unreadable) CRITICAL.Feb 26 14:46:49 [localhost:callhome.battery.failure:EMERGENCY]: Call home for BATTERY ('Bat Initial FCC' unreadable) CRITICAL.Feb 26 14:46:49 [localhost:callhome.battery.failure:EMERGENCY]: Call home for BATTERY ('Bat Charge Volt' unreadable) CRITICAL.Feb 26 14:46:49 [localhost:callhome.battery.failure:EMERGENCY]: Call home for BATTERY ('Bat Charge FET' unreadable) CRITICAL.Feb 26 14:50:10 [localhost:monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (Battery voltage unreadable for 5 mins)