  • The FAS2820 controller experiences an unexpected shutdown. 
  • The system logs indicate multiple battery sensor failures, resulting in an emergency environmental shutdown:

Feb 26 14:46:06 [localhost:callhome.battery.failure:EMERGENCY]: Call home for BATTERY ('Bat Volt' unreadable) CRITICAL.
Feb 26 14:46:07 [localhost:callhome.battery.failure:EMERGENCY]: Call home for BATTERY ('Bat Curr' unreadable) CRITICAL.
Feb 26 14:46:07 [localhost:callhome.battery.failure:EMERGENCY]: Call home for BATTERY ('Bat Dstg Cycles' unreadable) CRITICAL.
Feb 26 14:46:07 [localhost:callhome.battery.failure:EMERGENCY]: Call home for BATTERY ('Bat Charge Curr' unreadable) CRITICAL.
Feb 26 14:46:08 [localhost:callhome.battery.failure:EMERGENCY]: Call home for BATTERY ('Bat Dcharge FET' unreadable) CRITICAL.
Feb 26 14:46:49 [localhost:callhome.battery.failure:EMERGENCY]: Call home for BATTERY ('Bat Temp' unreadable) CRITICAL.
Feb 26 14:46:49 [localhost:callhome.battery.failure:EMERGENCY]: Call home for BATTERY ('Bat Full Cap' unreadable) CRITICAL.
Feb 26 14:46:49 [localhost:callhome.battery.failure:EMERGENCY]: Call home for BATTERY ('Bat Initial FCC' unreadable) CRITICAL.
Feb 26 14:46:49 [localhost:callhome.battery.failure:EMERGENCY]: Call home for BATTERY ('Bat Charge Volt' unreadable) CRITICAL.
Feb 26 14:46:49 [localhost:callhome.battery.failure:EMERGENCY]: Call home for BATTERY ('Bat Charge FET' unreadable) CRITICAL.
Feb 26 14:50:10 [localhost:monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (Battery voltage unreadable for 5 mins)

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.