Skip to main content
NetApp Knowledge Base

FAS2820 (DISK REDUNDANCY FAILED) ERROR occurs

Views:
168
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

Applies to

  • FAS2820
  • ONTAP 9

Issue

  • Autosupport  (DISK REDUNDANCY FAILED) ERROR is triggered from the node, resulting in degraded HA status on both nodes.

node-1: 

NetApp Release 9.14.1P6: Tue Jun 18 12:11:44 EDT 2024
    System ID: 0987654321 (node-1); partner ID: 0123456789 (node-2)
    System Serial Number: 95XXXXXXXXXX (node-1)
    System Rev: A6
    System Storage Configuration: Multi-Path HA 
<<< Before the issue, there is Tri-Path HA
    System ACP Connectivity: Inband Active
    SAS2/SAS3 Mixed Stack Support: all
    All-Flash Optimized: false
    Capacity Optimized: false
 All SAN Array: false
    Backplane Part Number: DS21212
    Backplane Rev: 
    Backplane Serial Number: 792XXXXXXXXX

 

node-2: 

NetApp Release 9.14.1P6: Tue Jun 18 12:11:44 EDT 2024
    System ID: 0123456789 (node-2); partner ID: 0987654321 (node-1)
    System Serial Number: 95XXXXXXXXXX (node-2)
    System Rev: A6
    System Storage Configuration: Mixed-Path HA 
<<< Before the issue, there is Tri-Path HA 
    System ACP Connectivity: Inband Active
    SAS2/SAS3 Mixed Stack Support: all
    All-Flash Optimized: false
    Capacity Optimized: false
 All SAN Array: false
    Backplane Part Number: DS21212
    Backplane Rev: 
    Backplane Serial Number: 792XXXXXXXXX

 

  • Upon checking the environment, the SAS cable [7] connected to node-2 appears to be disconnected and shows a status of <N/A>.

 SAS cable information by element:
   [1] Internal connector
   [2] Internal connector
   [3] Vendor: Molex Inc.
       Type: MINI-SAS HD passive copper 2m  ID: 00  Swaps: 0
       Serial number: 123456789  Part number: 112-00437+A0
   [4] Vendor: <N/A> (disconnected)
       Type: <N/A> <N/A> <N/A>  ID: <N/A>  Swaps: 0
       Serial number: <N/A>  Part number: <N/A>
   [5] Internal connector
   [6] Internal connector
   [7] Vendor: <N/A> (disconnected) 
       Type: <N/A> <N/A> <N/A>  ID: <N/A>  Swaps: 0
       Serial number: <N/A>  Part number: <N/A>
   [8] Vendor: <N/A> (disconnected)
       Type: <N/A> <N/A> <N/A>  ID: <N/A>  Swaps: 0
       Serial number: <N/A>  Part number: <N/A>

  • Before disconnected, the vendor name and type are displayed correctly.

    SAS cable information by element:
      [1] Internal connector
      [2] Internal connector
      [3] Vendor: Molex Inc.
          Type: MINI-SAS HD passive copper 2m  ID: 00  Swaps: 0
          Serial number: 123456789  Part number: 112-00437+A0
      [4] Vendor: <N/A> (disconnected)
          Type: <N/A> <N/A> <N/A>  ID: <N/A>  Swaps: 0
          Serial number: <N/A>  Part number: <N/A>
      [5] Internal connector
      [6] Internal connector
      [7] Vendor: Amphenol
          Type: MINI-SAS HD passive copper 0.5-1.0m  ID: 01  Swaps: 0
          Serial number: APF12345678901  Part number: 112-00435+A0
      [8] Vendor: <N/A> (disconnected)
          Type: <N/A> <N/A> <N/A>  ID: <N/A>  Swaps: 0
          Serial number: <N/A>  Part number: <N/A>
    ACP installed element list: 1, 2; with error: none

  • SAS ports [3] and [4] on FAS2820 controller A are designated as 0b1 and 0b2 ports, respectively. 
  • Similarly, on FAS2820 controller B, ports [7] and [8] are designated as 0b1 and 0b2 ports.

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.