FAS2620/FAS2650 down following (Battery PCT capacity critical) error
Applies to
- ONTAP 9
 - SP FW 5.10 and later
 - FAS2620/FAS2650
 
Issue
- 
    
(BATTERY (full charge capacity low)) EMERGENCYASUP triggered. 
HA Group Notification (BATTERY (full charge capacity low)) EMERGENCY
- Node down due to NVMEM Battery error.
 
[env_mgr: monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (Battery PCT capacity critical)
- Battery learning cycle doesn't occurred during node shutdown.
 
[IPMI.emergency]: triggered OS halt: Battery PCT capacity critic
[IPMI.notice]: d501 | 02 | EVT: 0301ffff | Attn_Sensor1 | Assertion Event, "State Asserted"
[ONTAP.notice]: Appliance user command halt.
[IPMI.notice]: d601 | 02 | EVT: 6f03ffff | Sensor 255 | Assertion Event, "Storage OS graceful shutdown"
[IPMI Event.critical]: System power down
[IPMI.emergency]: Shutdown by Data ONTAP
[Trap Event.critical]: hwassist abnormal_reboot (28)
[IPMI.notice]: d701 | 02 | EVT: 0300ffff | Power_Good | Assertion Event, "State Deasserted"
[ASUP.notice]: First notification email | (REBOOT (abnormal)) WARNING | Sent
- 
    
Bat Pct Capacitymarked as critical low. 
Bat Pct Capacity critlow 32 % 39 % 44 % -- --