Skip to main content
NetApp Knowledge Base

Ethernet connector warning for port XX cannot communicate with connector

Views:
122
Visibility:
Public
Votes:
0
Category:
disk-shelves
Specialty:
hw
Last Updated:

Applies to

  • ONTAP 9
  • FAS/AFF Systems
  • NS224 Disk Shelves

Issue

  • Ethernet connect warnings are reported on NSM module:
[Node-01: dsa_worker0: ses.status.etherConn.warn:error]: NS224NSM100 (S/N SHFNCXXXX000047) shelf 10 on channel 0x Ethernet connector warning for port e0a: cannot communicate with connector.  This element is on the rear of the shelf at the top, on module A.
[Node-01: dsa_worker0: ses.status.etherConn.warn:error]: NS224NSM100 (S/N SHFNCXXXX000047) shelf 10 on channel 0x Ethernet connector warning for port e0b: cannot communicate with connector.  This element is on the rear of the shelf at the top, on module A.
  • The nodes lose path via one NSM module and following alert is reported in event logs:
[Node-01: nchmd: hm.alert.raised:alert]: Alert Id = NoPathToNSMA_Alert , Alerting Resource = 17438XXXXXXXXXXXXX raised by monitor node-connect
[Node-01: dsa_disc: shelf.config.tospha:info]: System has transitioned to single path HA attached storage
[Node-01: dsa_disc: callhome.dsk.redun.fault:error]: Call home for DISK REDUNDANCY FAILED
  • Amber LED is seen on the affected NSM module.
  • Nodes transition to single-path HA configuration:

::> system node run -node <node> sysconfig -a

NetApp Release 9.8P12: Thu May 12 20:07:27 EDT 2022
    System ID: 0987654321 (Node-01); partner ID: 1234567890 (Node-02)
    System Serial Number: 8520XXXXX004 (Node-01)
    System Rev: A6
    System Storage Configuration: Single-Path HA

  • The SAS connect subsystem is degraded:

::> system health subsystem show -subsystem sas-connect

                   Subsystem: SAS-connect
                      Health: degraded
        Initialization State: initialized
Number of Outstanding Alerts: 1
 Number of Suppressed Alerts: 0
                        Node: Node-01, Node-02
  Subsystem Refresh Interval: 30m, 30m

  • The output of storage show fault shows the following:

::> system node run -node <node> storage show fault

Enclosure Status: unrecoverable
Channel: 0x
Shelf: 10
Shelf Type: NS224NSM100
Module Type: NSM100

Temperature Sensors:
Element Status         Status Bytes  Status Descriptions
  1: OK                01,00,27,00   
  2: OK                01,00,2D,00   
  3: OK                01,00,2D,00   
  4: OK                01,00,2D,00   
  5: OK                01,00,2E,00   
  6: OK                01,00,2E,00   
  7: OK                01,00,3D,00   
  8: UNRECOVERABLE     04,00,3A,00   
  9: UNRECOVERABLE     04,00,3A,00   
 10: OK                01,00,40,00 

Enclosure:
Element Status         Status Bytes  Status Descriptions
  1: OK                01,00,02,00   FAIL

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.