Enclosure with NO ACPP, INBACP, FAIL error
Applies to
- ONTAP 9
- AFF/FAS systems
- IOM12E shelf modules
Issue
- EMS reporting the below shelf faults:
[Node-02: statd: monitor.shelf.fault:alert]: Critical fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.
[Node-01: statd: monitor.shelf.fault:alert]: Critical fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.
[Node-01: statd: monitor.shelf.fault:alert]: Critical fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.
[Node-02: statd: callhome.shlf.fault:error]: Call home for SHELF_FAULT STORAGE-FAULT
output:::> system node run -node <node_name> -command storage show fault
Enclosure Status: critical
Channel: 0a
Shelf: 0
Shelf Type: DS224-12
Product Serial Number: XXXXXXXXXXXXXXX
Module Type: IOM12EEnclosure:
Element Status Status Bytes Status Descriptions
1: OK 01,00,02,00 FAIL
Vendor Unique Element 85-IOM12E: (ACP)
Element Status Status Bytes Status Descriptions
1 [IOM12E A] : CRITICAL 02,18,00,40 NO ACPP, INBACP, FAIL
2 [IOM12E B] : CRITICAL 02,18,00,40 NO ACPP, INBACP, FAIL- Issue remains after Service Processor reboot.
- Disabling and re-enabling the ACP on the system doesn't help.
- Power cycle of IOM does not resolve the issue.
- Reseating the Motherboard also results in the same error.