Skip to main content
NetApp Knowledge Base

Encountered a crash in exception log on IOM module error ses.IOMLogCrash

Views:
355
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

Applies to

  • ONTAP 9
  • IOM-6

Issue

  • Encountered a crash in Exception Log on IOM module B:
  • Below message will be seen in events log

NETAPP: [Node 1: ses.IOMLogCrash]: Encountered a crash in Exception Log on IOM module B SN [8XXXXX85] FW 0191, channel 0b.04.99 shelf ID 4 shelf SN [XXXXX]. #015

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.