Skip to main content
NetApp Knowledge Base

Enclosure services device reports Command aborted by host adapter

Views:
798
Visibility:
Public
Votes:
0
Category:
disk-shelves
Specialty:
hw
Last Updated:

Applies to

  • SAS shelves

Issue

  • Multiple minor events report for different nodes and shelves:
Minor 13:41:47 02/17/22 13:41:48 02/17/22 node_name-1 NetApp Enclosure services device shelf_switch-1:1.123L45: Command aborted by host adapter: HA status 0x4: cdb 0x1c (pls. check node_name-1syslog:/local/rsyslog/node_name-1) messages
Minor 13:41:47 02/17/22 13:41:47 02/17/22 node_name-3 NetApp Enclosure services device shelf_switch-1:1.123L45: Command aborted by host adapter: HA status 0x4: cdb 0x1c (pls. check node_name-1syslog:/local/rsyslog/node_name-3) messages
Minor 13:41:46 02/17/22 13:41:47 02/17/22 node_name-2 NetApp Enclosure services device shelf_switch-1:1.123L45: Command aborted by host adapter: HA status 0x4: cdb 0x1c (pls. check node_name-1syslog:/local/rsyslog/node_name-2) messages
  • Multiple EMS messages for SAS timeouts in different shelves and modules:
[node_name-1: isp2400_intrd: scsi.cmd.checkCondition.bridge.SAS.timeout:debug]: Enclosure services device shelf_switch-3:2.123L45: Check Condition: CDB 0x1c: Sense Data SCSI:aborted command - (0xb - 0x88 0x1 0xf)(9024).
[node_name-1: dsa_worker0: ses.exceptionShelfLog:debug]: Retrieving Exception SES Shelf Log information on channel shelf_switch-3:6 IOM module A disk shelf ID 1.
[node_name-1: isp2400_intrd: scsi.cmd.checkCondition.bridge.SAS.timeout:debug]: Enclosure services device shelf_switch-4:1.123L45: Check Condition: CDB 0x1c: Sense Data SCSI:aborted command - (0xb - 0x88 0x1 0xf)(9010).
[node_name-1: dsa_worker5: ses.exceptionShelfLog:debug]: Retrieving Exception SES Shelf Log information on channel shelf_switch-4:7 IOM module B disk shelf ID 2.
[node_name-1: isp2400_intrd: scsi.cmd.checkCondition.bridge.SAS.timeout:debug]: Enclosure services device shelf_switch-4:1.123L45: Check Condition: CDB 0x1c: Sense Data SCSI:aborted command - (0xb - 0x88 0x1 0xf)(9015).
[node_name-1: dsa_worker4: ses.exceptionShelfLog:debug]: Retrieving Exception SES Shelf Log information on channel shelf_switch-4:7 IOM module B disk shelf ID 2.
[node_name-1: isp2400_intrd: scsi.cmd.checkCondition.bridge.SAS.timeout:debug]: Enclosure services device shelf_switch-4:1.123L45: Check Condition: CDB 0x1c: Sense Data SCSI:aborted command - (0xb - 0x88 0x1 0xf)(9053).
[node_name-1: dsa_worker3: ses.exceptionShelfLog:debug]: Retrieving Exception SES Shelf Log information on channel shelf_switch-4:7 IOM module B disk shelf ID 2.
[node_name-1: isp2400_intrd: scsi.cmd.checkCondition.bridge.SAS.timeout:debug]: Enclosure services device shelf_switch-2:2.123L45: Check Condition: CDB 0x1c: Sense Data SCSI:aborted command - (0xb - 0x88 0x1 0xf)(9045).
[node_name-1: dsa_worker4: ses.exceptionShelfLog:debug]: Retrieving Exception SES Shelf Log information on channel shelf_switch-2:6 IOM module B disk shelf ID 3.
 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.