Emergency shutdown: Environmental Reason Shutdown (Battery power fault)
Applies to
AFF/FAS
Issue
- Node goes down with the following messages in the event logs:
[Node-01:nvram.battery.power.fault:EMERGENCY]: The NVRAM battery is not receiving power. To prevent data loss, the system will shut down in 5 minutes.
[Node-01:callhome.battery.failure:EMERGENCY]: Call home for BATTERY (power fault) CRITICAL.
[Node-01:monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (Battery power fault)
- Console message when booting:
WARNING: The battery is experiencing a critical failure:
- Battery power fault
Without a working battery, the system cannot retain data
during a power outage, which can result in data loss.
Power down the system and verify that the battery is
properly installed.
To ignore this failure and boot the system in a mode
where data loss might occur, press 'c' followed by 'Enter'
- System powered on and provided enough time to NVRAM battery to charge.
- SP/BMC firmware updated to the latest version available.