EMS reports “Automatic shutdown sequence canceled”
Applies to
- AFF systems
- ASA systems
- FAS systems
- ONTAP 9
Issue
EMS reports “Automatic shutdown sequence canceled”.
[env_mgr: monitor.shutdown.cancel:notice]: Automatic shutdown sequence canceled.
[env_mgr: monitor.chassisTemperature.ok:notice]: Chassis temperature is ok.
or
[env_mgr: monitor.shutdown.chassisOverTemp:EMERGENCY]: Chassis temperature is too hot: Multiple Internal Temp sensors are unreadable. System will be shutdown in 10 minutes
[env_mgr: monitor.shutdown.cancel:notice]: Automatic shutdown sequence canceled.
SP log shows the following messages:
(none) env_mgr[1283]: Payload EMS: EMS_monitor_shutdown_cancel
(none) env_mgr[1283]: Payload EMS: EMS_monitor_shutdown_cancel
(none) env_mgr[1283]: Payload EMS: EMS_monitor_chassisTemperature_ok