EMS Logs repeatedly report ses.status.ModuleError alert
Applies to
- NS224NSM16E
- Shelf Firmware 0140
Issue
- Both nodes are repeatedly reporting
ses.status.ModuleError:alertin theEMS-LOG-FILE.GZ, with Node1 reporting Module B and Node2 reporting Module A.
Node1: dsa_worker3: ses.status.ModuleError:alert]: NS224NSM16E (S/N XXXXXXXXXXXX) shelf 0 on channel 0s PCI switch error for PCI Switch 2: status not available; status not available. This element is on the rear of the shelf at the bottom, on shelf module (B).
Node2: dsa_worker0: ses.status.ModuleError:alert]: NS224NSM16E (S/N XXXXXXXXXXXX) shelf 0 on channel 0s PCI switch error for PCI Switch 1: status not available; status not available. This element is on the rear of the shelf at the top, on shelf module (A).
- In the
STORAGE-SHELF-PORT.XML, the module reported by each node shows a status ofUnknown, while the other module appears with a normal status.
Node1:
Shelf name: 0s.shelf0Shelf id: 0Channel: 0sModule: AShelf UID: 00:a0:98:00:00:XX:XX:XXShelf S/N: XXXXXXXXXXXXTerm switch: N/AShelf state: ONLINEModule state: OK
Shelf name: Partner.shelf0Shelf id: 0Channel: PartnerModule: BShelf UID: 00:a0:98:00:00:XX:XX:XXShelf S/N: XXXXXXXXXXXXTerm switch: N/AShelf state: ONLINEModule state: UNKNOWN
Node2:
Shelf name: Partner.shelf0Shelf id: 0Channel: PartnerModule: AShelf UID: 00:a0:98:00:00:XX:XX:XXShelf S/N: XXXXXXXXXXXXTerm switch: N/AShelf state: ONLINEModule state: UNKNOWN
Shelf name: 0s.shelf0Shelf id: 0Channel: 0sModule: BShelf UID: 00:a0:98:00:00:XX:XX:XXShelf S/N: XXXXXXXXXXXXTerm switch: N/AShelf state: ONLINEModule state: OK