During motherboard replacement partner node panic due to MDP
Applies to
Issue
- Partner node panic with following error at during giveback operation post motherboard replacement.
PANIC: aggr aggrX_node01: raid volfsm, fatal multi-disk error..
Raid type - raid_dp
Group name plex0/rg0 state NORMAL. 4 disks failed in the group.
Disk 0a.00.0P1 Shelf 0 Bay 0 [NETAPP X336_SCMNE04TA07 NA00] S/N [XXXXXXXXXXXXX] UID [XXXXXXX:XXXXXXX:XXXXXXX:XXXXXXX:00000000:00000000:00000000:00000000:00000000:00000000] error: disk does not exist.
Disk 0a.00.6P1 Shelf 0 Bay 6 [NETAPP X336_SCMNE04TA07 NA00] S/N [XXXXXXXXXXXXX] UID [XXXXXXX:XXXXXXX:XXXXXXX:XXXXXXX:00000000:00000000:00000000:00000000:00000000:00000000] error: disk does not exist.
Disk 0a.00.8P1 Shelf 0 Bay 8 [NETAPP X336_SCMNE04TA07 NA00] S/N [XXXXXXXXXXXXX] UID [XXXXXXX:XXXXXXX:XXXXXXX:XXXXXXX:00000000:00000000:00000000:00000000:00000000:00000000] error: disk does not exist.
Disk /aggr1_kgnas31_01/plex0/rg0/0a.00.10P1 Shelf 0 Bay 10 [NETAPP X336_SCMNE04TA07 NA00] S/N [XXXXXXXXXXXXX] UID [XXXXXXX:XXXXXXX in SK process config_thread on release 9.10.1P6 (C) on Fri May 24 16:31:00 JST 2024
- After MDP panic node reboot and the same issue do not occur at the second giveback operation.