During ONTAP upgrade node unable to perform giveback
Applies to
- AFF A20
- FAS 2720
Issue
- Node unable to perform giveback during ONTAP upgrade
- Ports e0a / e0b show as down
- Connect the cluster ports of each node and perform a loopback test. It is found that the Cluster port of one node is always in the Down state.
(cable e0a > e0b on the same node to check if port status is online)
NodeA:
::> net poor show
(network port show)
Node: NodeA
Speed(Mbps) Health
Port IPspace Broadcast Domain Link MTU Admin/Oper Status
--------- ------------ ---------------- ---- ---- ----------- --------
a0a Default Service up 1500 -/- healthy
e0M Default Management up 1500 auto/1000 healthy
e0a Cluster Cluster up 9000 auto/10000 healthy
e0b Cluster Cluster up 9000 auto/10000 healthy
e0c Default - up 1500 auto/10000 healthy
e0d Default - up 1500 auto/10000 healthy
e0e Default Snapmirror up 1500 auto/1000 healthy
e0f tempsnapmirror down 1500 auto/- -
NodeB:
::> net port show
(network port show)
Warning: Unable to list entries for vifmgr on node "NodeA": RPC:
Couldn't make connection [from mgwd on node "NodeB" (VSID: -1)to vifmgr at ****
Node: NodeB
Speed(Mbps) Health
Port IPspace Broadcast Domain Link MTU Admin/Oper Status
--------- ------------ ---------------- ---- ---- ----------- --------
a0a Default - up 1500 auto/10000 -
e0M Default - up 1500 auto/1000 -
e0a Cluster - down 9000 auto/auto -
e0b Cluster - down 9000 auto/auto -
e0c Default - up 1500 auto/10000 -
e0d Default - up 1500 auto/10000 -
e0e Default - up 1500 auto/1000 -
e0f - - down 1500 auto/auto -
8 entries were displayed.