Disk status is reported as "startup failed" after replacement
Applies to
- ONTAP 9
- All Platforms
Issue
- After replacing a faulty disk with a new one, the disk status is reported as "startup failed" in sysconfig -a logs:
::> system node run -node <node-name> -command sysconfig -a
00.15: NETAPP X423_TA15E900A10 NA00 0.0GB 0B/sect (Startup failed.)
- Disk initialization fails and the following messages are seen in the event logs:
Mon Mar 07 13:18:04 IST [Node-01: pmcsas_asyncd_0: scsi.path.excessiveErrors:error]: Excessive errors encountered by adapter 0a on disk device 0a.00.15.
Mon Mar 07 13:18:04 IST [Node-01: pmcsas_asyncd_0: scsi.cmd.pastTimeToLive:error]: Disk device 0a.00.15: request failed after try #6: cdb 0x1b.
Mon Mar 07 13:18:04 IST [Node-01: pmcsas_asyncd_0: disk.init.failure.error:warning]: Disk 0a.00.15 failed initialization due to error 6.
Mon Mar 07 13:18:10 IST [Node-01: pmcsas_intrd_0: disk.readReservationFailed:error]: Disk read reservation failed on 0a.00.15 CDB 0x5e:01 - SCSI:hardware error (4 c4 1)
Mon Mar 07 14:40:24 IST [Node-01: pmcsas_intrd_0: disk.reserveFailed:error]: Disk reservation failed on 0b.00.15 CDB 0x5e:01 - SCSI:hardware error (4 c4 1)
Mon Mar 07 14:40:24 IST [Node-01: sanown_io: diskown.errorDuringIO:error]: error 13 (fatal disk error) on disk 0a.00.15 (S/N ) while setting disk reservation
Mon Mar 07 14:40:24 IST [Node-01: disk_admin: disk.partner.msgStatus:info]: The partner/CDO has returned status 19 for msg sent for 0b.00.15.
Mon Mar 07 14:47:18 IST [Node-01: pmcsas_intrd_0: disk.init.failure.error:warning]: Disk 0a.00.15 failed initialization due to error 5.