Skip to main content
NetApp Knowledge Base

Disk redundancy fails for single disk

Views:
1,152
Visibility:
Public
Votes:
0
Category:
aff-series
Specialty:
hw
Last Updated:

Applies to

  • ONTAP 9
  • Call home for DISK REDUNDANCY FAILED

Issue

  • EMS alert and callhome
dsa_disc: callhome.dsk.redun.fault:error]: Call home for DISK REDUNDANCY FAILED
  • sysconfig -a output shows disk missing over a path
slot 0: SAS Host Adapter 0a (PMC-Sierra PM8070 rev. C, SAS, <UP>)
    [...]
    00.20: NETAPP   X371_S1643960ATE NA54 915.4GB 520B/sect (XXXXXXXXXXXXXX)
    00.21: NETAPP   X371_S1643960ATE NA54 915.4GB 520B/sect (XXXXXXXXXXXXXX)
    00.22: NETAPP   X371_S1643960ATE NA54 915.4GB 520B/sect (XXXXXXXXXXXXXX)
    00.23: NETAPP   X371_S1643960ATE NA54 915.4GB 520B/sect (XXXXXXXXXXXXXX)
    Shelf 0: DS224-12  Firmware rev. IOM12E A: 0240  IOM12E B: 0240
         
slot 0: SAS Host Adapter 0b (PMC-Sierra PM8070 rev. C, SAS, <UP>)
    [...]
    00.20: NETAPP   X371_S1643960ATE NA54 915.4GB 520B/sect (XXXXXXXXXXXXXX)
    00.21: NETAPP   X371_S1643960ATE NA54 915.4GB 520B/sect (XXXXXXXXXXXXXX)
    00.22: NETAPP   X371_S1643960ATE NA54 915.4GB 520B/sect (XXXXXXXXXXXXXX)
    Shelf 0: DS224-12  Firmware rev. IOM12E A: 0240  IOM12E B: 0240
  • Bay shows as Disabled/IDD in SAS expander phy state

Node01> sasadmin expander_phy_state
Expander phy state on 0b.0 (NETAPP  :DS22412IOM12E    SHFHUXXXXXXXXXXX):
                              Pwr         Invald Disprt Loss   Phy    CRC    Phy                    
                          Pwr Ccl Rsv Rls DWord  Error  Sync   Reset  Error  Change SATA            
PHY/BAY STATE             ON  Cnt Cnt Cnt Count  Count  Count  Prob   Cnt    Cnt    Affiliation     
------- ----------------- --- --- --- --- ------ ------ ------ ------ ------ ------ ----------------
29/21   12.0 Gb/s         YES 0   0   0   0      0      0      0      0      1      ----------------
30/22   12.0 Gb/s         YES 0   0   0   0      0      0      0      0      1      ----------------
31/23   Disabled/IDD      YES 0   0   0

  • Disk shows BYPASSED B

Disk Elements:
Element Status                  Status Bytes  Status Descriptions
  0 [Bay  0]: OK                01,00,00,00
  1 [Bay  1]: NONCRITICAL       03,01,10,04   ENCLOSURE BYPASSED B, BYPASSED B

  • In ADP configurations, partitions may not be seen for the node unable to see the disk

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.