Skip to main content
NetApp Knowledge Base

Disk redundancy failed seen due to faulting NSM140

Views:
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

Applies to

  • NX224
  • NSM140

Issue

  • Disk redundancy failed errors are seen daily:

HA Group Notification (DISK REDUNDANCY FAILED) ERROR

  • Errors communicating to disks through the affected module path ID are seen:

 [?]  Wed Aug 26 13:15:49 +0100 [node-01: scsi_cmdblk_strthr_admin: scsi.cmd.selectionTimeout:error]: Unknown device ?:?.?: Adapter/target error: HA status 0x7: cdb 0x12. Targeted device did not respond to requested I/O. I/O will be retried.
  [?]  Wed Aug 26 13:15:49 +0100 [node-01: scsi_cmdblk_strthr_admin: scsi.cmd.selectionTimeout:error]: Unknown device e11a.01.14.18L9998: Adapter/target error: HA status 0x7: cdb 0x12. Targeted device did not respond to requested I/O. I/O will be retried.
  [?]  Wed Aug 26 13:15:49 +0100 [node-01: scsi_cmdblk_strthr_admin: scsi.cmd.selectionTimeout:error]: Unknown device e11a.01.14.19L9998: Adapter/target error: HA status 0x7: cdb 0x12. Targeted device did not respond to requested I/O. I/O will be retried.

  • No path to disk through the affected module is seen in sktrace:

2026-08-28T04:48:30Z 97465075182131       [50:0] DISK_DRIVER_ERR:  disk_get_nvme_nsm_path: Unable to find a path via NSM-B for disk: e11a.01.2.6

2026-08-28T04:00:00Z 97373116913329       [50:0] DISK_DRIVER_ERR:  disk_get_nvme_nsm_path: Unable to find a path via NSM-B for disk: e11b.01.7.12

2026-08-25T04:57:21Z 832446483412949      [48:0] DISK_DRIVER_ERR:  disk_get_nvme_nsm_path: Unable to find a path via NSM-B for disk: e11a.01.6.18

2026-08-27T19:00:00Z 42292428145013       [88:0] DISK_DRIVER_ERR:  disk_get_nvme_nsm_path: Unable to find a path via NSM-B for disk: e11b.01.7.12 

  • Boot media errors are seen during bootup of NSM140:
nvme nvme0: I/O 7 (I/O Cmd) QID 1 timeout, aborting
nvme nvme0: I/O 8 (I/O Cmd) QID 1 timeout, aborting
nvme nvme0: I/O 9 (I/O Cmd) QID 1 timeout, aborting
nvme nvme0: I/O 10 (I/O Cmd) QID 1 timeout, aborting
nvme nvme0: I/O 11 (I/O Cmd) QID 1 timeout, aborting
nvme nvme0: I/O 7 QID 1 timeout, reset controller
nvme nvme0: I/O 1 QID 0 timeout, reset controller
nvme nvme0: Device not ready; aborting reset, CSTS=0x1
nvme nvme0: Abort status: 0x371        (×5)
nvme nvme0: Device not ready; aborting reset, CSTS=0x1
nvme nvme0: Removing after probe failure status: -19
nvme nvme0: Device not ready; aborting reset, CSTS=0x1

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.