Issue

  • ONTAP event log reporting disk(s) missing: 

    Example:

raid.config.filesystem.disk.missing: File system Disk /aggr1/plex0/rg0/SwitchA1:10.126L9 Shelf 0 Bay 8 [NETAPP X343_HCBFE1T8A10 NA06] S/N [123456789] UID [5000CCA0:0000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] is missing.

  • storage disk show skips over one disk:

Node1::> storage disk show -shelf 0
                     Usable           Disk    Container Container
Disk                   Size Shelf Bay Type    Type        Name      
---------------- ---------- ----- --- ------- ----------- --------- 
11.0.0               1.63TB     0   0 SAS     aggregate   Aggr1                        
11.0.1               1.63TB     0   1 SAS     aggregate   Aggr1                                                         
11.0.2               1.63TB     0   2 SAS     aggregate   Aggr1                                                          11.0.3               1.63TB     0   3 SAS     aggregate   Aggr1                                               
11.0.4               1.63TB     0   4 SAS     aggregate   Aggr1
11.0.5               1.63TB     0   5 SAS     aggregate   Aggr1            
11.0.6               1.63TB     0   6 SAS     aggregate   Aggr1                                     
11.0.7               1.63TB     0   7 SAS     aggregate   Aggr1
                                                                           >>>>>>>>> bay 8 is missing 
11.0.9               1.63TB     0   9 SAS     aggregate   Aggr1

  • Storage shelf shows unknown link on the bay the disk is missing on:

Partial Path Link Invalid Running Loss Phy CRC Phy
Disk Port Timeout Rate DWord Disparity Dword Reset Error Change
Id State Value (ms) (Gb/s) Count Count Count Problem Count Count
--------------------------------------------------------------------------------------------------
[HST0/P0:0 ] OK 7 12.0 0 0 0 0 0 1
[HST1/P0:1 ] OK 7 12.0 0 0 0 0 0 1
[HST2/P0:2 ] OK 7 12.0 0 0 0 0 0 1
[HST3/P0:3 ] OK 7 12.0 0 0 0 0 0 1
[HST4/P1:0 ] EMPTY 7 NA 0 0 0 0 0 0
[HST5/P1:1 ] EMPTY 7 NA 0 0 0 0 0 0
[HST6/P1:2 ] EMPTY 7 NA 0 0 0 0 0 0
[HST7/P1:3 ] EMPTY 7 NA 0 0 0 0 0 0
[HST8/P2:0 ] OK 7 12.0 0 0 0 0 0 1
[HST9/P2:1 ] OK 7 12.0 0 0 0 0 0 1
[HST10/P2:2] OK 7 12.0 0 0 0 0 0 1
[HST11/P2:3] OK 7 12.0 0 0 0 0 0 1
[HST12/P3:0] EMPTY 7 NA 0 0 0 0 0 2
[HST13/P3:1] EMPTY 7 NA 0 0 0 0 0 2
[HST14/P3:2] EMPTY 7 NA 0 0 0 0 0 2
[HST15/P3:3] EMPTY 7 NA 0 0 0 0 0 2
[ 0 ] OK 7 12.0 0 0 0 0 0 1
[ 1 ] OK 7 12.0 0 0 0 0 0 1
[ 2 ] UNKWN LNK 7 NA 0 0 0 0 0 16

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.