Skip to main content
NetApp Knowledge Base

Disk Shelf Temperature Warning

Views:
227
Visibility:
Public
Votes:
0
Category:
disk-shelves
Specialty:
hw
Last Updated:

Applies to

  • ONTAP 9
  • FAS/AFF
  • Disk Shelves

Issue

  • From the event logs we can see the following shelf warning reported:

[node2: dsa_worker3: ses.status.temperatureWarning:alert]: DS2246 (S/N SHFFG1451XXXXXX) shelf 11 on channel 0c temperature warning for Temperature sensor 4: non-critical status; overtemperature warning. Current temperature: 66 C (150 F). This module is on the rear of the shelf on the lower left power supply.
[node2: statd: monitor.shelf.warning:error]: Fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.
[node2: dsa_worker4: ses.status.temperatureInfo:info]: DS2246 (S/N SHFFG1451XXXXXX) shelf 11 on channel 0c temperature information for Temperature sensor 4: normal status.

  • The loaction of the sensor maps to PSU. 
  • The issue persists even after replacement of PSU.
  •   Shelf logs indicates that these  warnings are being set and cleared only through IOM B of  Shelf 

--------------------------------------------------------------
Shelflog start time: Tue Jan  9 05:01:59 GMT 2024
Controller Id: 536XXXXXX
Channel: 0a Shelf: 10 Module type: IOM6 Firmware rev: 0200
Shelf product id: DS224IOM6
Shelf Serial Number: SHFFG145XXXXXX
Module B Serial Number: 7904XXXXXX
Log ID: SHFFG1450000251_B_7f
Timestamp: Wed Feb 14 02:43:31 IST 2024
--------------------------------------------------------------
EVENT LOGS
Timestamp Tue Feb 13 21:13:32 2024 (2812 10:40:01.901)
Tue Feb 13 21:13:23 2024 ( 2812 10:39:53.292); 0304002D; M; ENC_MGT; env_control; 04; Temperature zone 3 is now: warning hot set
Tue Feb 13 21:13:24 2024 ( 2812 10:39:54.361); 0304002E; M; ENC_MGT; env_control; 04; Temperature zone 3 is now: warning hot cleared
Tue Feb 13 21:13:24 2024 ( 2812 10:39:54.361); 03040031; M; ENC_MGT; env_control; 04; Temperature zone 3 is now: OK
Tue Feb 13 21:13:25 2024 ( 2812 10:39:55.433); 0304002D; M; ENC_MGT; env_control; 04; Temperature zone 3 is now: warning hot set
Tue Feb 13 21:13:30 2024 ( 2812 10:39:59.716); 0304002E; M; ENC_MGT; env_control; 04; Temperature zone 3 is now: warning hot cleared
Tue Feb 13 21:13:30 2024 ( 2812 10:39:59.716); 03040031; M; ENC_MGT; env_control; 04; Temperature zone 3 is now: OK

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.